<aguerrieri at kannel dot org>
http://www.blogalex.com/
Sqlbox is a special Kannel box that sits between bearerbox and smsbox and uses a database queue to store and forward messages.
Sqlbox behaves similar to other Kannel boxes and share a compatible configuration file format and command line options.
It works between bearerbox and smsbox, intercept all messages and use a couple of database tables to process messages.
Messages are queued on a configurable table (defaults to send_sms) and moved to another table (defaults to sent_sms) afterwards.
You can also manually insert messages into the send_sms table and they will be sent and moved to the sent_sms table as well. This allows for fast and easy injection of large amounts of messages into kannel.
Modular architecture: Easily integrates into Kannel infrastructure.
Compatible configuration file format and command line arguments.
Supports most Kannel features.
sqlbox is being developed on Linux and OSX systems, and should be fairly easy to export to other Unix-like systems. However, we don't yet support other platforms, due to lack of time, although it should be working without major problems on Windows (through Cygwin), Mac OSX, Solaris and FreeBSD.
sqlbox requires the following software environment:
Kannel libraries (gwlib) installed.
C compiler and libraries for ANSI C, with normal Unix extensions such as BSD sockets and related tools. (GNU's GCC tool-chain is recommended)
GNU Make.
An implementation of POSIX threads ( pthread.h ).
DocBook processing tools: DocBook style-sheets, jade, jadetex, etc; see README , section `Documentation', for more information (pre-formatted versions of the documentation are available, and you can compile Sqlbox itself even without the documentation tools).
GNU autoconf
This chapter explains how to build and install sqlbox from source or from a binary package. The goal of this chapter is to get the module compiled and all the files in the correct places; the next chapter will explain how to configure it.
Note: If you are upgrading from a previous version, please look at Appendix A for any important information.
The source code to Sqlbox is available for download at http://www.kannel.org/download.shtml . It is available in various formats and you can choose to download either the latest release version or the daily snapshot of the development source tree for the next release version, depending on whether you want to use Sqlbox for production use or to participate in the development.
If you're serious about development, you probably want to use CVS, the version control system used by the Kannel project. This allows you to participate in Kannel development much more easily than by downloading the current daily snapshot and integrating any changes you've made every day. CVS does that for you. (See the Kannel web site for more information on how to use CVS.)
The documentation for Sqlbox consists of two parts:
User's Guide , i.e., the one you're reading at the moment.
The README and various other text files in the source tree.
You can also find general information on Kannel's website and information about existing problems at our bugtracker .
We intend to cover everything you need to install and use Sqlbox is in User's Guide , but the guide is still incomplete in this respect. The README is not supposed to be very important, nor contain much information. Instead, it will just point at the other documentation.
If you are using Sqlbox on a supported platform, or one that is similar enough to one, compiling Sqlbox should be trivial. After you have unpacked the source package of your choose, or after you have checked out the source code from CVS, enter the following commands:
./bootstrap ./configure makeThe bootstrap script uses autoconf to generate the files needed to build the module. The configure script investigates various things on your computer for the Sqlbox compilation needs, and writes out the Makefile used to compile the module. make then runs the commands to actually compile it.
If either command writes out an error message and stops before it finishes its job, you have a problem, and you either need to fix it yourself, if you can, or report the problem to the Kannel project. See Chapter 4 for details.
For detailed instruction on using the configuration script, see file INSTALL . That file is a generic documentation for configure . Sqlbox defines a few additional options:
--with-kannel-dir= DIR Where to look for Kannel Gateway libs and header files DIR points to the Kannel installation directory. Defaults to /usr/local
--disable-docs (default is --enable-docs) Use this option if you don't have DocBook installed and/or you want to save some time and CPU cycles. Pre-generated documentation is available on Kannel's site. Default behavior is to build documentation, b.e., converting the User Guide from the DocBook markup language to PostScript and HTML if DocBook is available.
--enable-drafts (default is --disable-drafts) When building documentation, include the sections marked as draft .
--with-ctlib=DIR Include Ct-Lib support. DIR is the Ct-Lib install directory, defaults to /opt/sybase.
--with-freetds=DIR Include FreeTDS Ct-Lib support. DIR is the FreeTDS install directory, defaults to /usr/local.
You may need to add compilations flags to configure:
CFLAGS='-pthread' ./configureThe above, for instance, seems to be required on FreeBSD. If you want to develop Sqlbox, you probably want to add CFLAGS that make your compiler use warning messages. For example, for GCC:
CFLAGS='-Wall -O2 -g' ./configure(You may, at your preference, use even stricter checking options.)
After you have compiled Kannel, you need to install the sqlbox binary in a suitable place. This is most easily done by using make again:
make bindir=/path/to/directory installReplace /path/to/directory with the pathname of the actual directory where the programs should be installed. This install the sqlbox binary:
gw/sqlbox |
This chapter explains how to configure and run Sqlbox and also how to tell if it's running from Kannel's HTTP interface.
There is only one configuration file for Sqlbox, and that file commands all aspects of its execution.
The configuration file can be divided into two parts: sqlbox configuration and database connection.
Details of each part are in appropriate sections later on this documentation.
The syntax used for the configuration file is the same used in Kannel. Skip this section if you are already familiar with it. Otherwise, keep on reading:
A configuration file consists of groups of configuration variables. Groups are separated by empty lines, and each variable is defined on its own line. Each group in Sqlbox configuration is distinguished with a group variable. Comments are lines that begin with a number sign ( # ) and are ignored (they don't, for example, separate groups of variables).
A variable definition line has the name of the variable, and equals sign ( = ) and the value of the variable. The name of the variable can contain any characters except whitespace and equals. The value of the variable is a string, with or without quotation marks ( ) around it. Quotation marks are needed if the variable needs to begin or end with whitespace or contain special characters. Normal C escape character syntax works inside quotation marks.
Perhaps an example will make things easier to comprehend:
01 # Sqlbox configuration 02 group = sqlbox 03 id = "my-sqlbox" 04 smsbox-id = "sqlbox" ... 11 log-level = 0 12 log-file = "/var/log/kannel/kannel-sqlbox.log" 13 14 #MySQL Connection 15 group = mysql-connection 16 id = "my-sqlbox" 17 host = localhost ...The above snippet defines an sqlbox instance with id my-sqlbox that identifies with bearerbox as sqlbox and also sets the log-level and file location. It also defines a MySQL connection to localhost.
Lines 1 and 14 are comment lines. Line 13 separates the two groups. The remaining lines define variables. The group type is defined by the group variable value.
The various variables that are understood in each type of configuration group are explained below.
Some variable values are marked as 'bool'. The value for variable can be like true, false, yes, no, on, off, 0 or 1. Other values are treated as 'true' while if the variable is not present at all, it is treated as being 'false'.
A configuration file may contain a special directive called include to include other file or a directory with files to the configuration processing.
This allows to segment the specific configuration groups required for several services and boxes to different files and hence to have more control in larger setups.
Here is an example that illustrates the include statement :
group = sqlbox id = my-sqlbox smsbox-id = sqlbox ... log-file = "/var/log/kannel/kannel-sqlbox.log" log-level = 0 include = "dbconn.conf"Above is the main sqlbox.conf configuration file that includes the following dbconn.conf file with all required directives for the database connection.
group = mysql-connection id = my-sqlbox host = localhost username = myuser password = mypass database = kannelThe above include statement may be defined at any point in the configuration file and at any inclusion depth. Hence you can cascade numerous inclusions if necessary.
At process start time inclusion of configuration files breaks if either the included file can not be opened and processed or the included file has been processed already in the stack and a recursive cycling has been detected.
The configuration file MUST always include an 'sqlbox' group for general configuration. This group should be the first group in the configuration file.
As its simplest form, 'sqlbox' group looks like this:
group = sqlbox id = sqlbox bearerbox-port = 13001Naturally this is usually not sufficient for any real use. Thus, one or more of the optional configuration variables are used. In following list (as in any other similar lists), all mandatory variables are marked with (m), while conditionally mandatory (variables which must be set in certain cases) are marked with (c) .
Table 3-1. Sqlbox Group Variables
Variable | Value | Description |
---|---|---|
group (m) | sqlbox | This is a mandatory variable |
smsbox-id (m) | string | This is the box id. |
global-sender | number | If no explicit number is given, this number is used when sending messages. |
bearerbox-host (m) | host-name | This is the host where bearerbox is running. |
bearerbox-port (m) | port-number | This is the port number used to connect to bearerbox. |
smsbox-port (c) | port-number | This is the port number to which the smsboxes, if any, connect. This can be anything you want. Must be set if you want to handle any SMS traffic. |
smsbox-port-ssl (o) | bool | If set to true, the smsbox connection module will be SSL-enabled. Your smsboxes will have to connect using SSL to sqlbox then. This is used to secure communication between sqlbox and smsboxes in case they are in separate networks operated and the TCP communication is not secured on a lower network layer. Defaults to "no". |
sql-log-table | table-name | Indicates the table where messages are copied after being sent. Defaults to sent_sms. |
sql-insert-table | table-name | Indicates the table where messages should be inserted to sent. Defaults to send_sms. |
log-file | filename | A file in which to write a log. This in addition to stdout and any log file defined in command line. |
log-level | number 0..5 | Minimum level of log-file events logged. 0 is for 'debug', 1 'info', 2 'warning, 3 'error' and 4 'panic' (see Command Line Options) |
A sample more complex 'sqlbox' group could be something like this:
group = sqlbox id = sqlbox-db smsbox-id = sqlbox #global-sender = "" bearerbox-host = localhost bearerbox-port = 13001 smsbox-port = 13005 smsbox-port-ssl = false sql-log-table = sent_sms sql-insert-table = send_sms log-file = "/var/log/kannel/kannel-sqlbox.log" log-level = 0
sqlbox needs a connection to a supported DB engine to operate. This connection is established at startup time and kept open until the box stops.
At the moment, sqlbox only supports MySQL and PostgreSQL, with support for other engines being planned.
The process of configuring a DB connection is simple: You need to create a [engine]-connection section (where [engine] is the DB engine name, either mysql or pgsql) and indicate a few parameters needed to establish the DB connection.
Table 3-2. Sqlbox Database connection configuration variables
Variable | Value | Description |
---|---|---|
group | mysql-connection | This is a mandatory variable if we're connecting to a MySQL database. |
group | pgsql-connection | This is a mandatory variable if we're connecting to a PostgreSQL database. |
id (m) | string | An id to identify which external connection should be used for Sqlbox storage. Any string is acceptable, but semicolon ';' may cause problems, so avoid it and any other special non-alphabet characters. |
host (m) | string | The hostname where the DB engine is running. |
username (m) | string | The username used to connect to the DB engine. |
password (m) | string | The password used to connect to the DB engine. |
database (m) | string | The database name to use to store the data. |
max-connections | number | Create a pool with this number of connections open. |
Uses a MySQL database to store the data. You need to specify the mysql-connection group.
Here is an example configuration:
group = mysql-connection id = my-sqlbox host = localhost username = foo password = bar database = kannel max-connections = 1
Uses a PostgreSQL database to store the data. You need to specify the pgsql-connection group.
Here is an example configuration:
group = pgsql-connection id = pg-sqlbox host = localhost username = foo password = bar database = kannel max-connections = 1
You need to start sqlbox after starting the bearerbox, otherwise it won't have a port open to connect to. The preferred way to do this is to include sqlbox into your Kannel's startup script.
If you want to start it from command line (for testing, for example), give the following command:
/path/to/sqlbox -v 1 [config-file]The
-v 1
sets the logging level to
INFO. This way, you won't see a large amount of
debugging output (the default is DEBUG). Full
explanation of Sqlbox command line arguments is below.[config-file] is the name of the configuration file you are using with Sqlbox. The basic distribution packet comes with a sample configuration file you can use with some minor tweakings (check on the /examples folder. Feel free to edit the file to suit your needs.
Of course you need to have the bearerbox running before starting the box. Without the bearer box, sqlbox won't even start.
Sqlbox accept certain command line options and arguments when they are launched. These arguments are:
Table 3-3. Sqlbox Command Line Options
-v <level> | Set verbosity level for stdout (screen) logging. Default is 0, which means 'debug'. 1 is 'info, 2 'warning', 3 'error' and 4 'panic' |
--verbosity <level> | |
-D <places> | Set debug-places for 'debug' level output. |
--debug <places> | |
-F <file-name> | Log to file named file-name, too. Does not overrun or affect any log-file defined in configuration file. |
--logfile <file-name> | |
-V <level> | Set verbosity level for that extra log-file (default 0, which means 'debug'). Does not affect verbosity level of the log-file defined in configuration file, not verbosity level of the stdout output. |
--fileverbosity <level> | |
-H | Only try to open HTTP sendsms interface; if it fails, only warn about that, do not exit. (smsbox only) |
--tryhttp | |
-g | Dump all known config groups and config keys to stdout and exit. |
--generate | |
-u <username> | Change process user-id to the given. |
--user <username> | |
-p <filename> | Write process PID to the given file. |
--pid-file <filename> | |
-d | Start process as daemon (detached from a current shell session). Note: Process will change CWD (Current working directory) to /, therefore you should ensure that all paths to binary/config/config-includes are absolute instead of relative. |
--daemonize | |
-P | Start watcher process. This process watch a child process and if child process crashed will restart them automatically. |
--parachute | |
-X <scriptname> | Execute a given shell script or binary when child process crash detected. This option is usable only with --parachute/-P. Script will be executed with 2 arguments: scriptname 'processname' 'respawn-count'. |
--panic-script <scriptname> |
Sqlbox creates it's DB tables on the fly if the tables are not present at that moment. If you're upgrading from a previous version, or happen to have tables with the same names as the ones Sqlbox uses, but having a different structure, this will probably cause problems and there's a good chance the process will panic and stop. In that case, rename/drop the offending tables or change the names Sqlbox uses by using the sql-log-table and sql-insert-table variables.
One of the nice features Sqlbox provides is the ability to insert MT messages into Kannel's queue by inserting rows into the send_sms table. Keep in mind that both tables have the same schema, but you only need to care about send_sms. Sqlbox will move messages to the sent_sms table autmatically after processing it.
The tables structure is as follows:
Table 3-4. Sqlbox Database structure
Value | Type | Description | sendsms equivalent |
sql_id | BIGINT(20) | This is the auto-incremented PRIMARY KEY and should be always left alone. Set it to NULL or do not include it in your INSERT query. | - |
momt | ENUM('MO', 'MT') | Specifies if the message is either MO or MT. You should always use "MT" here. | - |
sender | VARCHAR(20) | Phone number of the sender. If this variable is not set, sqlbox global-sender is used. | from |
receiver | VARCHAR(20) | Phone number of the receiver. | to |
msgdata | TEXT | Contents of the message, URL encoded as necessary. The content can be more than 160 characters, but then Kannel's sendsms-user group must have max-messages set more than 1. | text |
udhdata | BLOB | Optional User Data Header (UDH) part of the message. Must be URL encoded. | udh |
time | BIGINT(20) | An integer timestamp. You can uses UNIX_TIMESTAMP() on MySQL or any similar function here. You can also leave the field empty/alone if you don't care about having a timestamp on your messages. | - |
smsc_id | VARCHAR(255) | Optional virtual smsc-id from which the message is supposed to have arrived. This is used for routing purposes, if any denied or preferred SMS centers are set up in SMS center configuration. This variable can be overridden on Kannel with a forced-smsc configuration variable. Likewise, the default-smsc variable can be used to set the SMSC if it is not set otherwise. | smsc |
service | VARCHAR(255) | Optional. Service name from which the message is supposed to have arrived. This field is logged as SVC in the log file so it allows you to do some accounting on it if your front end uses the same username for all services but wants to distinguish them in the log. | smsc |
account | VARCHAR(255) | Optional. Account name or number to carry forward for billing purposes. This field is logged as ACT in the log file so it allows you to do some accounting on it if your front end uses the same username for all services but wants to distinguish them in the log. In the case of a HTTP SMSC type the account name is prepended with the service-name (username) and a colon (:) and forwarded to the next instance of Kannel. This allows hierarchical accounting. | account |
id | BIGINT(20) | Kannel's internal message identifier. This have no meaning when you're inserting your own messages, since Kannel doesn't have an identifier on your message yet. Leave it alone. | - |
sms_type | BIGINT(20) | A numeric value indicating if it's an MO, MT or DLR message. ALWAYS INSERT A "2" HERE (Meaning: MT), OTHERWISE KANNEL'S QUEUE WILL GET CORRUPTED IF YOU RESTART IT AND YOU HAVE PENDING MESSAGES. | - |
mclass | BIGINT(20) | Optional. Sets the Message Class in DCS field. Accepts values between 0 and 3, for Message Class 0 to 3, A value of 0 sends the message directly to display, 1 sends to mobile, 2 to SIM and 3 to SIM toolkit. | mclass |
mwi | BIGINT(20) | Optional. Sets Message Waiting Indicator bits in DCS field. If given, the message will be encoded as a Message Waiting Indicator. The accepted values are 0,1,2 and 3 for activating the voice, fax, email and other indicator, or 4,5,6,7 for deactivating, respectively. [a] | mwi |
coding | BIGINT(20) | Optional. Sets the coding scheme bits in DCS field. Accepts values 0 to 2, for 7bit, 8bit or UCS-2. If unset, defaults to 7 bits unless a udh is defined, which sets coding to 8bits. | coding |
compress | BIGINT(20) | Optional. Sets the Compression bit in DCS Field. | compress |
validity | BIGINT(20) | Optional. If given, Kannel will inform SMS Center that it should only try to send the message for this many minutes. If the destination mobile is off other situation that it cannot receive the sms, the smsc discards the message. Note: you must have your Kannel box time synchronized with the SMS Center. | validity |
deferred | BIGINT(20) | Optional. If given, the SMS center will postpone the message to be delivered at now plus this many minutes. Note: you must have your Kannel box time synchronized with the SMS Center. | deferred |
dlr-mask | BIGINT(20) | Optional. Request for delivery reports with the state of the sent message. The value is a bit mask composed of: 1: Delivered to phone, 2: Non-Delivered to Phone, 4: Queued on SMSC, 8: Delivered to SMSC, 16: Non-Delivered to SMSC. Must set dlr-url on sendsms-user group or use the sendsms dlr-url variable or Sqlbox column. | dlr-mask |
dlr-url | VARCHAR(255) | Optional. If dlr-mask is given, this is the url to be fetched. (Must be url-encoded) | dlr-url |
pid | BIGINT(20) | Optional. Sets the PID value. (See ETSI Documentation). Ex: SIM Toolkit messages would use something like pid=127, coding=1, alt-dcs=1, mclass=3 | pid |
alt-dcs | BIGINT(20) | Optional. If unset, Kannel uses the alt-dcs defined on smsc configuration, or 0X per default. If equals to 1, uses FX. If equals to 0, force 0X. | alt-dcs |
rpi | BIGINT(20) | Optional. Sets the Return Path Indicator (RPI) value. (See ETSI Documentation). | rpi |
charset | VARCHAR(255) | Charset of text message. Used to convert to a format suitable for 7 bits or to UCS-2. Defaults to WINDOWS-1252 if coding is 7bits and UTF-16BE if coding is UCS-2. | charset |
boxc_id | VARCHAR(255) | The bearerbox ID that should handle this message. You can usually leave this one alone. | charset |
binfo | VARCHAR(255) | Optional. Billing identifier/information proxy field used to pass arbitrary billing transaction IDs or information to the specific SMSC modules. For EMI2 this is encapsulated into the XSer 0c field, for SMPP this is encapsulated into the service_type of the submit_sm PDU. | binfo |
Notes: a. To set number of messages, use mwi=[0-3]&coding=0&udh=%04%01%02%<XX>%<YY>, where YY are the number of messages, in HEX, and XX are mwi plus 0xC0 if text field is not empty. |
As when you're using the sendsms interface, you don't need to specify all the columns in order to succesfully enqueue a message.
Here's an example query you can use to send a simple message using Sqlbox:
INSERT INTO send_sms ( momt, sender, receiver, msgdata, sms_type ) VALUES ( 'MT', '1234', '1234567890', 'Hello world', 2 );
The former example would send a message with text "Hello world" to number "1234567890". If possible, the sender would be set to "1234".
You can add other parameters to specify routing, charset encoding and any other settings your setup may require. Just remember, try to keep it simple whenever possible
This chapter explains where to find help with problems related to the gateway, and the preferred procedure for reporting bugs and sending corrections to them.
The Kannel development mailing list is devel@kannel.org. To subscribe, send mail to devel-subscribe@kannel.org. This is currently the best location for asking help and reporting bugs. Please include configuration file and version number.
This appendix includes pertinent information about required changes on upgrades.
As a general rule, always check the ChangeLog file before upgrading, because it may contain important information worth knowing before making any changes.
Sqlbox is a simple module that usually upgrades easily and without requiring any other changes.
In some cases, a change on the DB structure takes place and this requires changes on the DB schemas as well. Since sqlbox automatically generates its tables, the best approach for this kind of upgrades is to make sure that there's no messages pending, backup the tables contents (if there's no messages pending only the sent_sms table will have records), drop the tables and let sqlbox create the tables again. Alternatively you can check what changes are necessary and ALTER the tables yourself.